CHINAUST
Pull-Out Test
Axial tensile test of the spin-welded connector joint, pulled to failure on a universal testing machine.
- Standard
- SAE J2044-2009
- Requirement
- ≥ 1500 N axial
- Test speed
- 50 mm/min
- Measured peak
- ~2666 N — CONFIRM
- Acceptance
- No fracture, crack or slip