Axial tensile test of the spin-welded connector joint, pulled to failure on a universal testing machine.

Standard
SAE J2044-2009
Requirement
≥ 1500 N axial
Test speed
50 mm/min
Measured peak
~2666 N — CONFIRM
Acceptance
No fracture, crack or slip